Industry 01 / 11 · Construction

Quiet, clean power for every phase of the build.

Mobile battery storage that runs tower cranes, welfare cabins and site plant without a generator running all night. It moves with the programme, from groundworks to handover.

  • Up to 90%less generator runtime on a hybrid site
  • < 1 dayfrom delivery to first power
  • 24/7remote monitoring over 4G

Overview

Construction runs on temporary power. Most of it is wasted.

A typical site generator is sized for the crane’s peak but spends most of the day idling at a fraction of its rating, burning fuel and running up maintenance hours. At night it runs again just to keep welfare cabins, lighting and security cameras alive.

EMS storage takes the steady load and absorbs the peaks. The generator, if you keep one at all, runs briefly at its most efficient point to top the battery up, or not at all once a grid connection is in place.

Today’s challenge With EMS
  1. 01Generators oversized for crane peaks and idling the rest of the day

    Battery absorbs crane and hoist peaks, so a smaller supply covers the site

  2. 02Noise and fumes restrict night work and upset neighbours

    Silent, zero-emission operation for welfare, lighting and security overnight

  3. 03Waiting months for a permanent site supply

    Plug-and-play units on site in a day, charged from any available source

  4. 04Fuel deliveries, theft and refuelling labour

    Remote state-of-charge alerts and far fewer fuel runs

EMS Energy Intelligence

Storage that thinks ahead.

Smart energy management that learns how your construction site uses power and plans every kilowatt ahead of the peak.

  • Load forecasting
  • Smart dispatch
  • Predictive health
  • Fleet-wide visibility
EMS Intelligence · Construction Illustrative example
Forecast peak shaved43%
Supply limit55% of peak
Horizon24 h
Site demand Covered by battery Grid / generator limit
  • Crane lift window forecast 07:00–10:00. Battery pre-charged to 95% by 06:30.
  • Overnight load is 12% of peak. Generator held off for 13 hours.

Applications

Where EMS works in construction.

Replaces noisy temporary diesel generators with high-capacity hybrid battery storage, delivering continuous power for tower cranes, welfare units, and heavy plant without altering site workflows.

  • 01

    Tower cranes & hoists

    High peak, low average loads handled by the battery so the supply can be right-sized.

  • 02

    Welfare & site cabins

    Heating, lighting and drying rooms powered silently around the clock.

  • 03

    Electric plant & vans

    Charge e-excavators, telehandlers and site vans from the same unit.

  • 04

    Tools & temporary lighting

    100 kW industrial sockets for tools, pumps and tower lights.

Size your system

A first estimate, in seconds.

Move the sliders to match your site. We’ll suggest a starting storage size and system, using typical figures for construction. An engineer then refines it with your real load data.

  • Free, no-obligation load assessment
  • Sizing modelled on your real demand profile
  • Proposal with options and expected savings
EMS sizing assistant Construction
Daily energy–
Suggested storage–
Suggested system–
Diesel avoided / yr–
CO₂ avoided / yr–

Indicative only. Assumes up to 10 hours of battery autonomy with a 20% reserve and about 0.3 L of diesel avoided per kWh supplied.

Get an engineer-checked proposal

Deployment

From first call to first power.

A clear, managed path with one UK team accountable from assessment to long-term support.

  1. 1 Week 1

    Site & load assessment

    We review your site, load profile and energy sources, remotely or on site.

  2. 2 Week 2–3

    System design & sizing

    Engineers model the load, size storage and choose the right EMS systems.

  3. 3 From 4 weeks

    Delivery & commissioning

    Units arrive pre-integrated, connected and commissioned by our team.

  4. 4 Ongoing

    Monitor & optimise

    Live monitoring, smart dispatch and 24/7 UK engineering support.

FAQ

Questions from construction teams.

Can’t see your question? Our engineers answer within one working day.

Can the system move with us between project phases?

Yes. iTrailer and iMBase are built to be towed or lifted between areas of a site, or on to the next project. Nothing is trenched or fixed in place.

Do we still need a generator?

Many sites keep a smaller generator as a backup charging source. It runs for short periods at full efficiency to top the battery up, instead of idling all day. Sites with a grid supply often remove it entirely.

Will it run a tower crane?

Cranes have short, high peaks and a low average draw, which suits battery storage well. We size the unit from your crane’s rating and lift profile during the site assessment.

How do we know when it needs charging?

Each unit reports state of charge and alarms over 4G, so your site team and our engineers see the same live data and get alerts before power runs low.

Start with the challenge

Tell us what the site
needs to do.

Share the location, the load and what is getting in the way. Our team will help you work out which system, and how many, the job needs.

Speak to an EMS specialist Email a quote request